You topped up the boiler yesterday. Today the pressure is back below 1 bar. Or you open the filling valve and the gauge doesn’t move at all. If the pressure rises and then drops again, get the cause checked. If it never rises while you’re topping up, close the valves and check the filling connection. Here’s what you can do yourself and when to call a heating engineer.

Jump to:

How can you tell if your boiler is losing pressure?

Read the pressure on the boiler display or gauge once the heating system has cooled. For many boilers, the recommended filling pressure is around 1.5 to 2 bar. Check the manual for your model. The pressure can rise slightly as the heating warms up, so compare readings taken when the system is cold.

Low pressure can leave radiators lukewarm, trigger a fault code or cause the boiler to shut down. The pressure at which it shuts down varies by model. Write down the reading and any fault code. If you’ve just bled the radiators, the pressure may be a little lower afterwards.

When can you top up the boiler yourself?

If the pressure is low as a one-off, you can’t see any leaks and you know where the filling connection is, you can usually top up the system yourself. Let it cool and follow the manufacturer’s instructions. Some boilers have a built-in filling system.

  1. Look up the recommended filling pressure and find the correct filling valve in the manual.

  2. If you use a filling hose, follow the manual’s instructions to clear the air from the hose before filling the system.

  3. Top up slowly and watch the gauge. Close the valves when you reach the recommended pressure.

  4. If you need to bleed the radiators, follow the manual and check the pressure again once the system is cold.

Take a photo of the gauge when you’re done. You’ll be able to see how much the pressure has changed the next time you check it cold.

What if topping up doesn’t work?

Does the gauge stay put, or can’t you hear any water flowing? Close the valves before checking anything. Use the manual to confirm you’ve got the right water supply and filling valves. Check that the hose is attached properly and hasn’t kinked. Leave a stuck valve alone. If you hear water flowing but the pressure reading stays the same, stop filling and have an engineer check the filling system and gauge.

If the hose or a connection leaks while you’re filling, close the valves. Call an engineer if it keeps leaking, if you see water around the boiler or if you’re unsure which connection to use. If the pressure is simply low and you want help, you can book a boiler top-up.

Why does the pressure keep dropping?

If the pressure is back down later that day or a few days after topping up, look for damp around radiator valves, visible pipe joints and beneath the boiler. A small leak can leave rust marks or traces of dried droplets. Take a photo if you spot anything.

  • The pressure drops gradually. There may be a small leak at a radiator, in a pipe or inside the boiler. Some leaks are out of sight.

  • The pressure rises sharply as the heating comes on and falls again when it cools. The expansion vessel may have stopped working properly. It normally accommodates the expansion of heated water. If the pressure gets too high, water can escape through the pressure relief valve.

  • Water comes out of the pressure relief discharge pipe. High pressure may have opened the valve, or the valve itself may be leaking. A heating engineer can check the cause.

When should you call a heating engineer?

Book a visit if the pressure drops again soon after topping up, the gauge doesn’t respond during filling or the boiler keeps showing a fault. If the heating stops working or water comes out of the boiler, contact an engineer promptly. Leave the boiler casing closed. In the Netherlands, use a company with CO-vrij certification for servicing or repairing a gas boiler.

An engineer can check for leaks and test the expansion vessel, pressure relief valve, gauge and filling system as needed. For a one-off drop, you can book a boiler top-up. If you see a leak, book a repair for a leaking heating system. If the pressure keeps dropping with no visible leak or you see a fault code, book a boiler fault diagnosis and describe what’s happening.

How were Zoofy customers helped?

These examples come from reviews of jobs booked through Zoofy. Customers describe what the engineer checked or repaired and what happened afterwards.

  • A leaking radiator valve. A customer noticed a leak from the radiator valve in their baby’s room. The engineer replaced the valve and topped up the system. The customer appreciated the quick response, clear communication and how tidy the room was left.

  • A new expansion vessel and the heating back on. One customer said the engineer replaced the expansion vessel and refilled the system. The boiler later shut down with a fault. The engineer was easy to reach and talked the customer through bleeding the system. The customer said the heating worked again afterwards.

  • Recurring pressure loss with no leak found during the visit. Another customer said the team checked for a leak as soon as they heard the pressure kept falling. Everything looked fine during the visit. The review gives no confirmed cause or repair.

What matters to customers?

Customers appreciate knowing when the engineer will arrive, what was checked and what to look out for afterwards. One customer who booked a boiler top-up appreciated being shown how to do it themselves next time.

Less positive reviews show what can go wrong when a job needs a follow-up. A customer with a leaking boiler said the engineer needed to order parts, was hard to reach and missed follow-up appointments. Another customer said they were charged while the problem remained unresolved. Ask what the visit covers and agree who’ll get in touch if parts are needed or the pressure drops again.

When you book through Zoofy, include the make and model, the pressure before and after topping up and any fault code. Say how quickly the pressure drops and attach a photo if you spot damp. You’ll see the rate when you book and pay through Zoofy afterwards.

Frequently asked questions about boiler pressure

Is boiler pressure below 1 bar too low?

For many boilers, yes. The recommended filling pressure is often around 1.5 to 2 bar when the system is cold. Check your boiler manual for the correct pressure and the point at which your model may shut down.

Why does the boiler pressure drop soon after topping up?

A radiator valve, pipe or the boiler itself could be leaking. If the pressure rises sharply when the heating is on and falls again once it cools, the expansion vessel could be involved. Note how the pressure changes and have a heating engineer investigate.

Why doesn’t the pressure rise when I top up the boiler?

Close the valves and check the manual to make sure you’re using the correct filling connection and the hose is fitted properly. If you can hear water flowing but the reading doesn’t change, stop filling and have the filling system and gauge checked.

Can my boiler lose pressure without a visible leak?

Yes. A small leak can be hard to spot, especially around a radiator valve, in a concealed pipe or inside the boiler. If the pressure keeps dropping between readings taken when the system is cold, call a heating engineer.

Is it normal for boiler pressure to drop after bleeding the radiators?

Yes, the pressure can be slightly lower afterwards. Check it once the system has cooled and top up according to the manual if needed. If it falls again without any more bleeding, have an engineer take a look.

Schedule a professional right away? Quickly find a reliable professional in your area.
Book your job →
Wilm Everts

My name is Wilm, a construction and home improvement expert at Zoofy, with many years of experience in the construction and renovation sector. Over the years, I have supervised countless projects, ranging from small maintenance jobs to full-scale renovations. This hands-on experience has taught me how essential transparency in pricing and quality is for every project.

At Zoofy, I share my knowledge about construction costs, pricing, and smartly comparing jobs. Whether it’s the cost of a painter, a plumber’s hourly rate, or the price of a complete bathroom renovation, I help you understand what a fair price is and what to look out for.

My goal is to make home improvement projects more transparent, so everyone knows where their money goes. By combining up-to-date pricing information with real-world experience, I make it easier to find the right professional—without any surprises afterward.